Installation & Operating Manual
The Harman FireLuxe Direct Vent Gas Stove
With Top Cooking Burner System
WARNING: If the information in these in-
structions is not followed exactly, a fire or
explosion may result causing property dam-
age, personal injury or loss of life.
- WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Immediately call your gas supplier from a
neighbor’s phone. Follow the gas sup-
plier’s instructions.
If you cannot reach your gas supplier, call
the fire department.
- Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
This appliance may be installed in an after-
market, permanently located manufactured
home (USA only) or in a mobile home, where
not prohibited by local codes.
This appliance is for use only with the type of
gas indicated on the rating plate. This appli-
ance is not convertible for use with other
gases, unless a certified conversion kit is used.
C
Ce manual est disponsible en Français sur demande.
- Do not store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this
or any other appliance.
Report # 135-S-15-5
Seitenansicht 0
1 2 3 4 5 6 ... 31 32

Inhaltsverzeichnis

Seite 1 - Report # 135-S-15-5

Installation & Operating Manual The Harman FireLuxe Direct Vent Gas Stove With Top Cooking Burner System WARNING: If the information in these

Seite 2

10 VENTING VERTICAL RISE IN FEET HORIZONTAL RUN IN FEET NATURAL GAS VENTING IF YOUR VENTING CONFIGURA-TION FALLS ABOVE THIS DOT-TED LINE, SEE PAGE 12

Seite 3 - TABLE OF CONTENTS

11 VENTING VERTICAL RISE IN FEET HORIZONTAL RUN IN FEET PROPANE (LP) GAS VENTING IF YOUR VENTING CONFIGURA-TION FALLS ABOVE THIS DOT-TED LINE, SEE PA

Seite 4 - IMPORTANT SAFETY INFORMATION

12 VENTING PLEASE NOTE: If your specific venting configuration falls in a box in the venting charts (on pages 10 & 11) that is above the dotted

Seite 5 - SPECIFICATIONS

13 VENT TERMINAL CLEARANCES VENTING Venting terminals shall not be recessed into a wall or siding.

Seite 6 - INSTALLATION

14 ASSEMBLY UNPACKING AND PLACING THE FIRELUXE By now, you will have removed the shipping carton from the base pallet. The FireLuxe is shipped on sp

Seite 7

15 ASSEMBLY LEFT REAR LOG RIGHT REAR LOG LEFT REAR LOG RECESS RIGHT REAR LOG RECESSES LEFT FRONT LOG RECESS RIGHT FRONT LOG RECESS PINS LOGS AND EMBE

Seite 8

16 ASSEMBLY Place the left front log next. Again, there is a recess on the burner top that corresponds to the shape of the flat base of the log. Pl

Seite 9

17 ASSEMBLY When correctly placed, the logs and embers will look like the illustration below. LATCHING DETAIL- PULL FORWARD AND DOWN TO HOOK LATCH OV

Seite 10

18 ASSEMBLY It is now time to install the ashlip on the stove front and to install the stove front and stove top. The ashlip is secured to the front

Seite 11 - VENTING

19 ASSEMBLY The remote control handset is powered by a 9-volt battery. There is a low battery indicator on the handset display panel. To replace th

Seite 12

2 AVERTISSEMENT: Assurez-vous de bien suivre les instructions données dans cette notice pour réduire au minimum le risque d’incindie ou d’explosion o

Seite 13

20 ASSEMBLY The main heating valve battery pack is located at the center rear of the stove. A removable valve access panel covers the valve componen

Seite 14 - ASSEMBLY

21 AIR INLET AND EXHAUST OUTLET RESTRICTORS The FireLuxe is equipped with externally adjustable restrictors for both the inlet air and the exhaust ou

Seite 15

22 You will now see the two guide plates. The guide plates have a pointer that corresponds to a letter scale for the air adjustment and number scale

Seite 16

23 FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property da

Seite 17

24 LIGHTING AND OPERATION 1. To turn the cooking burner off, turn the knob to the OFF, full clockwise position. TO TURN OFF GAS TO MAIN BU

Seite 18

25 LIGHTING AND OPERATION COOKING BURNER OPERATION The cooking burner on your FireLuxe functions like a cooking burner on any conventional kitchen ra

Seite 19

26 LIGHTING AND OPERATION REMOTE CONTROL HANDSET OPERATION AND PROGRAMMING Flame Height Adjustment PILOT FLAME ADJUSTMENT The pilot flow is fact

Seite 20

27 LIGHTING AND OPERATION SET OFF UP DOWN Radio Frequency Interference A frequency code is preset for the valve receiver and remote handset, but can

Seite 21

28 MAINTENANCE A qualified service agency should conduct an annual inspection and maintenance of your FireLuxe includ-ing the overall installation an

Seite 22

29 MAINTENANCE INSPECTING THE VENTING An inspection of both the inner and outer vent pipes and the vent terminal should be made as part of the an-nua

Seite 23 - LIGHTING AND OPERATION

3 TABLE OF CONTENTS IMPORTANT SAFETY INFORMATION 4 SPECIFICATIONS 5 INSTALLATION 6 MASSACHUSETTS REQUIREMENTS 7 VE

Seite 24

30 PARTS LIST *This is a quick response thermocouple. Replace it only with Part No. 3-40-09906

Seite 25

31 HARMAN GOLD WARRANTY 6 YEAR TRANSFERABLE LIMITED WARRANTY (Residential) 1 YEAR LIMITED WARRANTY (Commercial) Harman Stove Company warrants its

Seite 26

32 For replacement parts and customer service, contact your Harman Stove dealer. Manufactured by: HARMAN STOVE COMPANY 352 MOUNTAIN HOUSE ROAD

Seite 27

4 IMPORTANT SAFETY INFORMATION The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, AN

Seite 28 - MAINTENANCE

5 SPECIFICATIONS MAIN BURNER Natural Gas Propane (LP) Input Rating-Btu/hr 36000

Seite 29

6 INSTALLATION MINIMUM CLEARANCES TO COMBUSTIBLE CONSTRUCTION Stove to Left Side Wall 6” (150mm) Stove to Corner Wall 6” (150

Seite 30 - PARTS LIST

7 INSTALLATION The gas stove is shipped with a flexible connector that has a 1/2” NPT female connection. The gas supply piping should have a separat

Seite 31 - HARMAN GOLD WARRANTY

8 VENTING The FireLuxe Gas Stove has been tested and listed for installation with 4” X 6 5/8” Simpson DuraVent GS, AmeriVent Direct, Security Secure

Seite 32

9 VENTING Example 2 Fuel = Propane (LP) Vertical Rise = 6 feet Horizontal Run = 8 feet Elbows = 3 Equiv. Horizontal Run = 16 feet (8+4+4) Air Restric